Wires and Cables•Brand: RR Kabel

FIRE ALARM CABLE

Application These cables are used in high rise buildings , commercial complexes , schools and educational institutions , hospitals , etc. for connection with security systems like smoke detectors, emergency lightings, exit signboards and fire command centers . These cables are used where fire safety is of utmost importance . Standard BS 7629-1, BS EN 50200. Technical Data Voltage Rating: 300/500V Temperature Range: -30°C to +70°C (The cable should not be flexed when either the ambient or cable t

Technical Specifications

Application

These cables are used in high rise buildings, commercial complexes, schools and educational institutions, hospitals, etc. for connection with security systems like smoke detectors, emergency lightings, exit signboards and fire command centers. These cables are used where fire safety is of utmost importance.

Standard

BS 7629-1, BS EN 50200.

Technical Data

  • Voltage Rating: 300/500V
  • Temperature Range: -30°C to +70°C (The cable should not be flexed when either the ambient or cable temperature is below 0°C)
  • Minimum Bending Radius: 6D

Cable Type – 1

FFX200 05mSOZ1-R – CU/MGT/SR/OSCR/LSZH 300/500V Class 2

Cable Construction

Plain annealed copper conductor to BS EN 60228, class 2. Primary insulation of glass mica fire resistant tape. Secondary insulation of high performance silicone rubber (EI 2 to BS 7655 Section 1.1).

Core Colours: 2 Core – Blue, Brown; 3 Core – Blue, Brown, Black; 4 Core – Blue, Brown, Black, Grey.

Includes glass fiber tape, tinned copper earth/drain wire, aluminium fire barrier screen, and LSZH outer sheath (LTS3 to BS 7655 section 6.1).

Properties Low smoke zero halogen (LSZH), flame retardant. Fire Performance Tests Meets BS 7629-1 standards for 300/500V fire resistant cables with non-corrosive gases and low smoke emission. Category STANDARD 30 & STANDARD 60 per BS EN 50200, and ENHANCED 120 per BS 8434-2. Complies with BS 5839-1, clause 26 2e. Range Details
Part Number No. of Cores & Nominal Area (Sq.mm) No. of Strands / Strand Dia (mm) Nominal Overall Diameter (mm)
100100201105 2 x 1.5 7/0.53 10.0
100100201205 2 x 2.5 7/0.67 11.5
100100301105 3 x 1.5 7/0.53 10.8
100100301205 3 x 2.5 7/0.67 12.3
100100401105 4 x 1.5 7/0.53 12.0
100100401205 4 x 2.5 7/0.67 13.5
Electrical Properties
Part Number No. of Cores & Area (Sq.mm) Max. Conductor Resistance (Ω/km) Current Rating (A) Voltage Drop (mV/A/m)
100100201105 2 x 1.5 12.1 17.5 / 20.0 29
100100201205 2 x 2.5 7.41 24.0 / 27.0 18
100100301105 3 x 1.5 12.1 17.5 / 20.0 29
100100301205 3 x 2.5 7.41 24.0 / 27.0 18
100100401105 4 x 1.5 12.1 17.5 / 20.0 29
100100401205 4 x 2.5 7.41 24.0 / 27.0 18

Cable Type – 2

FFX200 05SOZ1-U – CU/SR/OSCR/LSZH 300/500V Class 1

Plain annealed copper conductor to BS EN 60228, class 1. Insulation of high performance ceramified silicone rubber (EI 2 to BS 7655 Section 1.1). Includes glass fiber tape, tinned copper earth/drain wire, aluminium fire barrier screen, and LSZH sheath (LTS3).

Core Colours: 2 Core – Blue, Brown; 3 Core – Blue, Brown, Black; 4 Core – Blue, Brown, Black, Grey.

Fire Performance Tests Complies with BS 7629-1 and BS EN 50200 (STANDARD 60) and meets 30 min survival time (Annex E). Conforms to BS 5839-1, clause 26 2d. Cable Design Parameters
Part Number Cores & Area (Sq.mm) No. of Strands / Strand Dia (mm) Overall Dia (mm)
100200200001 2 x 1 1/1.13 7.5
100200201105 2 x 1.5 1/1.38 8.5
100200201205 2 x 2.5 1/1.78 9.9
100200301105 3 x 1.5 1/1.38 9.1
100200301205 3 x 2.5 1/1.78 10.7
100200401105 4 x 1.5 1/1.38 10.1
100200401205 4 x 2.5 1/1.78 11.6
Electrical Properties
Part Number Cores & Area (Sq.mm) Resistance (Ω/km) Current Rating (A) Voltage Drop (mV/A/m)
100200200001 2 x 1 18.1 13.1 / 15.5 44
100200201105 2 x 1.5 12.1 17.5 / 20.0 29
100200201205 2 x 2.5 7.41 24.0 / 27.0 18
100200301105 3 x 1.5 12.1 17.5 / 20.0 29
100200301205 3 x 2.5 7.41 24.0 / 27.0 18
100200401105 4 x 1.5 12.1 17.5 / 20.0 29
100200401205 4 x 2.5 7.41 24.0 / 27.0 18

Cable Type – 3

FFX200 05mZOZ1-R – Cu/MGT/LS0H /OSCR/LSZH 300/500V Class 2

Plain annealed copper conductor to BS EN 60228, class 2. Primary insulation of glass mica tape and secondary LSZH insulation to BS EN 50363-5 (EI5). Includes glass fiber tape, tinned copper drain wire, aluminium screen, and LSZH sheath.

Fire Performance Tests Complies with BS 7629-1 and BS EN 50200 (STANDARD 60) and meets 30 min survival (Annex E). Fulfills BS 5839-1, clause 26 2d. Cable Design Parameters
Part Number Cores & Area (Sq.mm) No. of Strands / Strand Dia (mm) Overall Dia (mm)
100300201105 2 x 1.5 7/0.53 8.6
100300201205 2 x 2.5 7/0.67 9.7
100300301105 3 x 1.5 7/0.53 9.4
100300301205 3 x 2.5 7/0.67 10.9
100300401105 4 x 1.5 7/0.53 10.4
100300401205 4 x 2.5 7/0.67 11.8
Electrical Properties
Part Number Cores & Area (Sq.mm) Resistance (Ω/km) Current Rating (A) Voltage Drop (mV/A/m)
100300201105 2 x 1.5 12.1 17.5 / 20.0 29
100300201205 2 x 2.5 7.41 24.0 / 27.0 18
100300301105 3 x 1.5 12.1 17.5 / 20.0 29
100300301205 3 x 2.5 7.41 24.0 / 27.0 18
100300401105 4 x 1.5 12.1 17.5 / 20.0 29
100300401205 4 x 2.5 7.41 24.0 / 27.0 18

Code Designation

Example: FFX200 05mSOZ1-R

Where:

  • FFX200 = Fire Resistant Cable Series
  • 05 = 300/500V
  • m = Mica Tape
  • S = Silicone Rubber
  • O = Screened
  • Z1 = LSZH Outer Sheath
  • R = Class 2 Conductor

Request Official Quotation

Direct B2B pricing with GST invoice & contractor quantity discounts.

Complementary Engineering Stock

Related & Compatible Products from RR Kabel

View All Catalog Items

BTC Insights

Guides related to this product

All articles
RR KabelBrand Comparisons
6 min read

RR Kabel vs Other Wire Brands: What Indian Industries Should Know Before Buying

RR Kabel vs Other Wire Brands: What Indian Industries Should Know Before Buying When it comes to industrial electrical systems, the selection of wire brands not just becomes a purchasing choice but an investment in safety, efficiency and sustainable use. Given the competition of cable manufacturers

Read the guide
Industrial Electrical CableCables & Wires
5 min read

How to Choose the Right Electrical Cable for Industrial Use ?

How To Choose The Right Electrical Cable For Industrial Use? In the industrial sector, the electrical wiring of a factory, warehouse, or manufacturing facility can be considered the system of central nervous conduits in the plant. However, unlike electrical wiring found within the domestic space, in

Read the guide