Solar Cable – IS 17293
RR Kabel
1/1
Direct Channel Assurance Certified
100% Genuine OEM
Batch Test Reports
IS & IEC Compliant
Factory Warranty
Wires and Cables•Brand: RR Kabel

Solar Cable – IS 17293

Solar Cable (DC Solar / Photovoltaic) - IS 17293 Marked Application & Standards Flexible single core Solar cables, popularly known as DC Solar or Photovoltaic cables, are used for interconnection between various elements in photovoltaic (PV) systems, including roof top PV systems in residential or commercial buildings, PV panels / module interconnection, between panel and string box, or from string box to inverter. These are used as free hanging, movable or fixed installations in various indoor,

Technical Specifications

Solar Cable (DC Solar / Photovoltaic) - IS 17293 Marked

Application & Standards

Flexible single core Solar cables, popularly known as DC Solar or Photovoltaic cables, are used for interconnection between various elements in photovoltaic (PV) systems, including roof top PV systems in residential or commercial buildings, PV panels / module interconnection, between panel and string box, or from string box to inverter. These are used as free hanging, movable or fixed installations in various indoor, outdoor, hazard explosion areas, in industries as well as in agriculture. They are suitable for applications in equipment with protective insulations (protecting class II).

Statutory Requirement

The Quality Control Order (QCO) on DC Solar Cable released by Ministry of Commerce & Industry on 24th August 2023, mandates the use of DC Solar cable marked with IS 17293 in India. Any person who contravenes the provisions of this Order shall be punishable under the provisions of the Bureau of Indian Standards Act, 2016.

  • Standard: IS 17293:2020
  • Compliance: RR Kabel Solar Cable marked with IS 17293 complies with IEC 62930 and exceeds the requirements of EN 50618.

Technical Data & Construction

  • Voltage Rating (AC): 1.0/1.0 kV
  • Max. PV-System Voltage (DC): up to 2.0 kV possible
  • Max. Permissible Operating Voltage (AC): 0.7/1.2 kV
  • Max. Permissible Operating Voltage (DC): 0.9/1.8 kV
  • Short-Circuit Temperature: 250°C (referring to period of 5 sec.)
  • Operating Temperature Range: -40°C to +90°C
  • Minimum Bending Radius (Fixed): approx. 4 x cable Ø

Cable Construction Details:

  • Conductor: Fine wire bunch of annealed **tinned copper** conductors according to IS 8130
  • Insulation: UV resistant crosslinked **Halogen Free Flame Retardant** core insulation
  • Core Identification: Red, Black or Natural
  • Sheath: UV resistant crosslinked **Halogen Free Flame Retardant** sheath over insulation
  • Cable Colour: Black, Red, Black with red strip (or as required)

Properties (Safety and Performance)

  • Ultraviolet (UV) resistant
  • Weather (Ozone) resistant
  • Damp-Heat resistant (tested for 1000 hours at 90°C and 85% humidity)
  • Non-toxic & Non-corrosive
  • Smoke emission is negligible & transparent
  • Excellent water resistant
  • Acid and alkali resistant
  • Ammonia resistant
  • Self-extinguishing and flame retardant according to IS 10810 part 53 & 62

Part Number Suffix Key

Please complete the part numbers by adding the suffix (in place of ‘xx’) for the insulation colour required:

02 – black
03 – red
Black with red strip (or as required)

Cable Design and Current Capacity Parameters

Part Number Nominal Cross Sectional Area (Sq. mm) Insulation Thickness (mm) Outer sheath Thickness (mm) Approx. Cable Diameter (mm) as per EN 50618 Current carrying capacity according to method of installation (A) Max. Conductor Resistance at 20°C, (Ω/Km)
Single cable free in air (A) Single cable on a surface (A) Two loaded cables touching, on a surface (A)
12010101xx01 1.5 0.70 0.80 4.66 30 29 24 13.7
12010102xx01 2.5 0.70 0.80 5.09 41 39 33 8.21
12010103xx01 4.0 0.70 0.80 5.59 55 52 44 5.09
12010104xx01 6.0 0.70 0.80 6.13 70 67 57 3.39
12010105xx01 10.0 0.70 0.80 7.07 98 93 79 1.95
12010106xx01 16.0 0.70 0.90 8.32 132 125 107 1.24
12010107xx01 25.0 0.90 1.00 10.14 176 167 142 0.795
12010108xx01 35.0 0.90 1.10 11.49 218 207 176 0.565
12010109xx01 50.0 1.00 1.20 13.33 276 262 221 0.393
12010110xx01 70.0 1.10 1.20 15.19 347 330 278 0.277
12010111xx01 95.0 1.10 1.30 16.94 416 395 333 0.210
12010112xx01 120.0 1.20 1.30 18.71 488 464 390 0.164
12010113xx01 150.0 1.40 1.40 20.86 566 538 453 0.132
12010114xx01 185.0 1.60 1.60 23.24 644 612 515 0.108
12010115xx01 240.0 1.70 1.70 26.14 755 736 620 0.0817

*Construction Product Regulation (CPR) is a regulation issued by the European Union with the purpose of regulating the limits of fire resistance and dangerous substances in the materials used in construction. This regulation applies to all products intended to be incorporated, permanently, in construction. (Above link provides the DOP (declaration of performance) for the CPR compliance for the product.)

Request Official Quotation

Direct B2B pricing with GST invoice & contractor quantity discounts.

Complementary Engineering Stock

Related & Compatible Products from RR Kabel

View All Catalog Items

BTC Insights

Guides related to this product

All articles
RR KabelBrand Comparisons
6 min read

RR Kabel vs Other Wire Brands: What Indian Industries Should Know Before Buying

RR Kabel vs Other Wire Brands: What Indian Industries Should Know Before Buying When it comes to industrial electrical systems, the selection of wire brands not just becomes a purchasing choice but an investment in safety, efficiency and sustainable use. Given the competition of cable manufacturers

Read the guide
Industrial Electrical CableCables & Wires
5 min read

How to Choose the Right Electrical Cable for Industrial Use ?

How To Choose The Right Electrical Cable For Industrial Use? In the industrial sector, the electrical wiring of a factory, warehouse, or manufacturing facility can be considered the system of central nervous conduits in the plant. However, unlike electrical wiring found within the domestic space, in

Read the guide