Description
Application
These cables are used for intrinsically safe circuits. For hazard-prone areas, cables with blue sheath are used for controlling and measuring requirements. These installations are not earthed and require a separate power circuit. Tinned copper braid screen ensures disturbance-free transmission of data and signals.
Standard
Adapted to DIN EN 60079-14: VDE 0165 Part 1.
Technical Data
- Nominal Voltage: UO / U 300 / 500V
- Insulation Resistance: Min. 20 GΩ x cm
- Temperature Range: Flexing -5°C to +70°C; Fixed installation -30°C to +70°C
- Minimum Bending Radius: Flexing 20 x cable ø; Fixed installation 6 x cable ø
- Test Voltage: 3000V
- Mutual Capacitance: Core to core (approx.) – 140 nF/km; Core to screen (approx.) – 185 nF/km
- Inductance: 0.68 mH/km (approx.)
Cable Construction
- Bare copper, fine wire conductors, to DIN/BS EN 60228 Cl.5
- Core insulation of special PVC TI2 EN 50363-3
- Black core with continuous white numbering according to DIN VDE 0293
- Cores stranded in layers with optimal lay-length
- Plastic foil over the laid-up cores
- Tinned-copper braided screen, approx. 85% coverage
- Outer sheath of special PVC, TM2 to DIN/BS EN 50363-4.1
- Colour: Blue (RAL 5015)
Properties
- PVC self-extinguishing and flame retardant according to IEC 60332-1-2
Cable Design Parameters
| Part Number | No. of Cores & Nominal Cross Sectional Area (Sq. mm) | Approx. Cable Diameter (mm) | Approx. Copper Weight (kg/km) | Approx. Cable Weight (kg/km) |
|---|---|---|---|---|
| 031600201075 | 2 x 0.75 | 6.2 | 25 | 53.2 |
| 031600201075 | 3 x 0.75 | 6.5 | 31.3 | 64.0 |
| 031600201075 | 4 x 0.75 | 7.0 | 39.0 | 77.0 |
| 031600201075 | 4G 0.75 | 7.0 | 39.0 | 77.0 |
| 031600201075 | 5 x 0.75 | 7.7 | 47.2 | 93.4 |
| 031600201075 | 7 x 0.75 | 8.3 | 62.0 | 116.4 |
| 031600201075 | 12 x 0.75 | 10.9 | 98.9 | 189.7 |
| 031600201075 | 18 x 0.75 | 12.7 | 141.0 | 265 |
| 031600201075 | 25 x 0.75 | 14.8 | 210.6 | 363.6 |
| 031600201075 | 2 x 1 | 6.5 | 29.5 | 59.7 |
| 031600201075 | 3 x 1 | 6.8 | 38.9 | 73.6 |
| 031600201075 | 4 x 1 | 7.3 | 49.1 | 89 |
| 031600201075 | 5 x 1 | 8.1 | 58.4 | 108.1 |
| 031600201075 | 7 x 1 | 8.8 | 77.2 | 136.8 |
| 031600201075 | 12 x 1 | 11.5 | 125.5 | 223.3 |
| 031600201075 | 18 x 1 | 13.9 | 180 | 328.9 |
| 031600201075 | 25 x 1 | 15.9 | 266.1 | 439.8 |
| 031600201075 | 2 x 1.5 | 7.1 | 39.4 | 73.9 |
| 031600201075 | 3 x 1.5 | 7.5 | 51.7 | 92.7 |
| 031600201075 | 4 x 1.5 | 8.2 | 66.2 | 115.9 |
| 031600201075 | 5 x 1.5 | 8.9 | 80.9 | 138.7 |
| 031600201075 | 7 x 1.5 | 9.9 | 108 | 182.3 |
| 031600201075 | 12 x 1.5 | 13 | 175.1 | 298 |
| 031600201075 | 18 x 1.5 | 15.6 | 276 | 450.8 |
| 031600201075 | 25 x 1.5 | 17.9 | 377.6 | 596.4 |
Note: x = Without green/yellow earth core (OZ)
For current ratings to DIN VDE 0298-4 refer table no. 12-3 of Appendix