LI2Y(ST)CY PIMF

LI2Y(ST)CY PIMF

Enquire on WhatsApp

Description

Application

Absolute disturbance-free data transfer both for installed terminals in all areas of medicine and data technology. Also suitable for use in machine tool and steel producing industries, traffic signal systems, assembly lines and food processing.

Technical Data

  • Standard: Based on VDE 0812
  • Voltage Grade (Not for power installation): Max. 250 V
  • Test Voltage: Core / core 2000 V. Core / screen 1000V
  • Insulation Resistance: Min. 5000 GΩ x cm
  • Mutual Capacitance:
    • 0.22 mm² max., 70 nF/km
    • 0.34 mm² max., 70 nF/km
    • 0.5 mm² max., 75 nF/km
    • 1 mm² max., 85 nF/km
  • Inductance: Approx. 0.4 mH/km
  • Cross-Talk Attenuation: Min. 80 dB up to 1 MHZ
  • Characteristic Impedance at: approx. 85 Ω (>1 MHz)
  • Minimum Bending Radius: Fixed 10 x cable ø
  • Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C

Cable Construction

  • Bare copper stranded 7 wire conductor.

Conductor make-up for

  • Flame retardant according to EN 60332-1-2.
  • Special PE insulation ensures low mutual capacitance, lower dielectric loss, low screen interference currents.
  • Low capacitance design allows a longer cable connection between frequency converter and motor.
  • Meets EMC requirements.
  • Due to the optimal screening an interference-free operation of frequency converters is obtained.

Conductor Resistance (loop) at 20°C

  • 0.22 mm² = 186 Ω/km (max.)
  • 0.34 mm² = 115 Ω/km (max.)
  • 0.5 mm² = 78.5 Ω/km (max.)
  • 0.75 mm² = 58 Ω/km (max.)
  • 1 mm² = 39.2 Ω/km (max.)
  • Core colours as per DIN 47100 (Refer table no. 2-1 of appendix)
  • PiMF : (pair in metal foil) cores twisted in pairs, foil wrapped plastic coated aluminium foil and copper drain-wire tinned,
  • 100% coverage.
  • PiMFs are stranded in layer.
  • Core wrapping with plastic tapes.
  • Overall copper screened braiding, 85 % coverage
  • Special PVC outer sheath TM2, to EN 50363-4.1.
  • Colour grey (RAL 7032).

Properties

  • PVC self-extinguishing and flame retardant according to EN 60332-1-2. The twisted-pair lay-up prevents electrical unbalances within the cable and this thus effectively suppresses cross-talking effects.

Cable Design Parameters

Part Number No. of Pairs & Nominal Cross Sectional Area (Sq. mm) Approx. Cable Diameter (mm) Approx. Copper Weight (kg/km) Approx. Cable Weight (kg/km)
050700221022 2 x 2 x 0.22 2 x 2 x 0.22 33.5 76
050700321022 3 x 2 x 0.22 3 x 2 x 0.22 47.8 96
050700421022 4 x 2 x 0.22 4 x 2 x 0.22 68.8 127
050700821022 8 x 2 x 0.22 8 x 2 x 0.22 191.2 286
050701021022 10 x 2 x 0.22 10 x 2 x 0.22 284.0 398
050700221034 2 x 2 x 0.34 2 x 2 x 0.34 44.1 90
050700321034 3 x 2 x 0.34 3 x 2 x 0.34 67.2 120
050700421034 4 x 2 x 0.34 4 x 2 x 0.34 97.5 161
050700821034 8 x 2 x 0.34 8 x 2 x 0.34 283.3 389
050701021034 10 x 2 x 0.34 10 x 2 x 0.34 421.5 548
050700221050 2 x 2 x 0.5 2 x 2 x 0.5 56.3 106
050700321050 3 x 2 x 0.5 3 x 2 x 0.5 88.8 146
050700421050 4 x 2 x 0.5 4 x 2 x 0.5 132.7 203
050700521050 5 x 2 x 0.5 5 x 2 x 0.5 185.7 268
050700821050 8 x 2 x 0.5 8 x 2 x 0.5 405.5 523
050701021050 10 x 2 x 0.5 10 x 2 x 0.5 591.3 731
050700220001 2 x 2 x 1 2 x 2 x 1 76.3 138
050700320001 3 x 2 x 1 3 x 2 x 1 116.1 187
050700420001 4 x 2 x 1 4 x 2 x 1 167.3 254
050701020001 10 x 2 x 1 10 x 2 x 1 636.3 808

 