Our Products

JZ-EB

Application :-
  • Installation of intrinsically safe circuits.
Standard :-
  • Adapted to DIN EN 60079-14: VDE 0165 Part1.
Technical Data :-
  • Nominal Voltage : U / U 300 / 500V O
  • Nominal Voltage : U / U 300 / 500V. < 50V AC < 75V DC O
  • Insulation Resistance : Min. 20 GΩ x cm
  • Temperature Range : Flexing -5°C to +70°C.
  • Fixed installation -30°C to +70°C
  • Minimum Bending Radius : Flexing 15 x cable ø. Fixed installation 4 x cable ø
  • Test Voltage : 4000V
Cable Construction :-
  • Bare copper, fine wire conductors, to EN 60228 Cl.5.
  • Special PVC core insulation TI2, to EN 50363-3.
  • Black Core with continuous white numbering to DIN VDE 0293.
  • Green/yellow earth core in outer layer (3 cores and above).
  • Cores stranded in layers with optimal lay-length.
  • Outer sheath of special PVC, TM2 to DIN/BS EN 50363-4.1.
  • Colour Black (RAL 9005).
Cable Design Parameters :-
Part NumberNo. of Cores and Nominal Cross Sectional Area (Sq. mm)Approx. Cable Diameter (mm)Approx. Copper Weight (kg/km)Approx. Cable Weight (kg/km)
0315002010752 x 0.755.34.544
0315003010753 x 0.755.61.554
0315004010754 x 0.756.18.566
0315005010755 x 0.756.96.085
03150121107512G 0.7510.185.5190
03150181107518G 0.7511.9128.0273
03150251107525G 0.7514.6178.0396
0315002000012 x 15.619.052
0315003000013 x 16.028.566
0315004000014 x 16.838.086
0315005000015 x 17.547.5104
0315007000017 x 18.966.5148
03150120000112 x 111.1114.0239
03150180000118 x 113.2171.0346
0315002011052 x 1.56.329.069
0315003011053 x 1.56.743.587
0315004011054 x 1.57.358.0109
0315005011055 x 1.58.272.5137
0315003111053 G 1.56.743.587
0315004111054 G 1.57.358.0109
0315005111055 G 1.58.272.5137
03150181110518G 1.514.5260.0455
03150251110525G 1.517.2361.0637